Landlord electrical safety and EICRs: the complete guide

Landlord Electrical Safety and EICR Guide: Requirements in England

Landlords in England are responsible for more than arranging an electrical inspection every five years. The fixed installation must remain safe, a qualified person must inspect and test it when required, tenants must receive the right records, and defects found during an inspection or reported later must be dealt with appropriately. An Electrical Installation Condition Report (EICR) is central to that process, but it is a record of the installation at a particular point in time, not a guarantee against future faults.

  • Day or nightEmergency help, day or night
  • Local responseArrival estimate confirmed when you call
  • Qualified assessmentNICEIC Registered Electricians
  • Clear pricingNo hidden costs
  • 17 min read
  • Updated 25 Oct 2026
  • Trusted by local customers
  • 5.0 rated locally
Electrician kneeling to record inspection results beside an open consumer unit in a rented flat hallway

What are a landlord’s electrical safety and EICR duties in England?

Landlord electrical safety and EICR rules in England require covered rented homes to have the fixed electrics inspected and tested by a qualified person at least every five years, or sooner if the report says. Tenants must receive the report, and required remedial work or further investigation must be completed within 28 days or the report’s shorter period.

What the law and official guidance say

Is your rental property compliant?

The inspection date, the codes, the remedial evidence and the tenant notices all have to line up.

Practical advice from our electricians

The landlords who struggle are rarely the ones with old wiring. They are the ones whose report, remedial paperwork and tenant notices sit in three different inboxes. Keep one property file with the dates, the codes and the written confirmation, and most compliance problems disappear.

Ali VahidiFounder & Managing Director

A clear guide to electrical inspections, tenant paperwork, remedial work, rental-property responsibilities and when professional help is needed.

This guide explains the wider responsibilities for private and social rented homes, the meaning of a satisfactory or unsatisfactory EICR, the timetable for sharing reports and acting on findings, and the practical information a landlord or letting agent should have ready before booking an inspection. For the exact legal framework and exceptions, refer to the GOV.UK guidance for private and social rented homes, listed in the official guidance at the end of this guide; the responsibilities below apply to England rather than automatically to every part of the UK.

A quotation is not confirmation that a defect has been corrected, and a booked appointment is not proof that the installation is safe.

Printed electrical inspection report open on a kitchen worktop with a pen, keys and a tablet

Landlord electrical safety duties in England

England’s electrical safety regulations require covered rented homes to meet the relevant standards for their electrical installations. The legislation began with the private rented sector and was extended to social rented housing in 2025. In ordinary terms, landlords must arrange inspection and testing of fixed electrics by a qualified person at intervals of no more than five years, obtain the resulting report, act on necessary defects and provide the required documents to tenants and councils. If the report calls for an earlier reinspection, the shorter period applies.

The report sits alongside wider duties to maintain the property. A tenant reporting scorching, exposed wiring or a socket affected by water is not something to postpone until the next scheduled EICR. Likewise, an EICR is not a substitute for a focused investigation of an active fault. The existing TRACEFORM guide Landlord Electrical Emergency Obligations addresses the immediate response to a tenant-reported electrical hazard; this pillar concentrates on the full inspection, compliance and record-keeping picture.

The regulations do not cover every possible residential arrangement in the same way. Government guidance identifies exceptions, including some owner-sharing arrangements, certain long leases and particular institutional accommodation. Before relying on a general rule, check the nature of the tenancy, who controls the installation and whether additional licensing or housing duties apply. A managing agent can coordinate the work, but delegating the appointment does not, by itself, remove the landlord’s underlying legal responsibilities.

If the report recommends reinspection in three years, the three-year date applies, not the five-year maximum.

What an EICR measures — and what it does not

An EICR assesses the condition of the fixed electrical installation within the agreed inspection scope. That ordinarily includes wiring, socket outlets, light fittings, the consumer unit, earthing and bonding arrangements, and relevant permanently connected equipment. The inspector considers signs of deterioration and electrical safety risks, and carries out suitable testing. Some circuits or equipment may be inaccessible; limitations and observations should be recorded rather than assumed away.

An EICR is not a certificate saying an old installation must comply with every detail of a newly published standard. The competent inspector evaluates the installation’s condition and whether it can continue to be used safely, taking account of its age, the applicable standards and the observations found. An older consumer unit is not automatically unsafe simply because a newer design exists. For the role of protective devices and assessing a fuse board, see TRACEFORM’s guide to consumer unit and electrical protection.

An EICR also does not ordinarily certify portable appliances, the effectiveness of repairs performed months later, or a property’s general fitness in every respect. Its purpose is not to quote for replacing the entire installation. A separate investigation, remedial certificate or follow-up assessment may be necessary depending on what the inspector discovers and what work is subsequently undertaken.

A letting agent can coordinate the work, but delegating the appointment does not remove the landlord’s legal responsibilities.

How frequently a rental property needs an EICR

For covered tenancies, the maximum normal interval is five years, or the shorter interval stated in the most recent report. The landlord should plan ahead of the deadline, allowing time for tenant access, inspection and any necessary remedial work. A report that recommends another inspection in three years should not be treated as valid for five simply because that is the statutory maximum.

A change of tenant does not automatically mean a fresh five-year EICR is due every time a property is re-let. The landlord should establish whether a suitable current report exists, whether the next inspection date has passed, whether defects have been resolved and whether any significant change to the installation calls for further assessment. New tenants must receive the required report before occupation. If the condition of the installation is uncertain, a qualified inspector should determine whether the existing evidence is sufficient.

For multi-property landlords, the inspection date is only one of several dates to track. The report’s recommended next inspection, any investigation deadline and the date remedial confirmation was supplied can all differ. Keeping one current property record avoids overlooking an action that may otherwise disappear between the electrician, managing agent and landlord.

Private rented and social rented homes

The statutory inspection framework now extends beyond private landlords. According to the GOV.UK guidance for private and social rented homes, social rented tenancies granted after 1 December 2025 fall under the expanded requirements, while older social housing tenancies have transitional provisions. For those existing tenancies, the initial inspection of installations and checks of relevant landlord-provided electrical equipment must be completed before 1 November 2026. Subsequent checks follow the prescribed intervals. Landlords should verify their exact obligations against the current guidance rather than copying a pre-2025 private-sector summary.

There is an additional distinction for electrical equipment in social rented homes. Social landlords must arrange checks of electrical equipment they provide under the tenancy, with appropriate records, whereas the fixed-installation EICR and electrical equipment checks are not the same task. In private rented property, landlords still have duties to supply and maintain safe appliances, but it would be misleading to describe the social-sector five-year equipment-check rule as an identical blanket requirement for every private landlord.

In practice, the first question for a housing provider is which properties and equipment the applicable rules cover. The second is whether there is a reliable record of inspections and checks already carried out. This prevents unnecessary repeat visits while identifying homes or items for which the required evidence is missing.

Preparing for an EICR inspection

Give the electrician the property address, access contact, existing EICR, any installation certificates and a description of relevant changes or reported symptoms. A complete previous report can make it easier to compare old and new observations. Where tenants work from home, need essential electrical equipment or have access restrictions, agree the arrangements in advance because testing may require individual circuits to be isolated for short periods.

The inspection should be carried out by a suitably qualified person competent in periodic inspection and testing. Registration with a recognised scheme can help with supplier checks, but the contractor’s actual inspection competence, experience and relevant insurance still matter. Ask what areas will be inspected, how limitations will be recorded, what documentation will be supplied and how any immediate danger discovered during the visit will be handled. TRACEFORM’s EICR inspection and testing service page sets out its inspection and reporting work separately from emergency fault callouts.

A letting agent may handle booking and keys, but the landlord or authorised manager should still know who can approve additional investigation or isolation if a serious defect is found. There is little value in an inspection slot that cannot safely proceed because no one has confirmed access to the consumer unit, locked rooms or relevant shared supplies.

Reading the EICR result and classification codes

The report identifies observations and gives an overall assessment of the installation’s condition. A satisfactory result does not mean every component is new or that no improvements could ever be made; it indicates the inspection has not found observations that make the installation unsatisfactory for continued use within the reported scope. Conversely, an unsatisfactory outcome needs action on the findings identified, not an automatic instruction to rewire the entire property.

Inspectors use C1 for danger present and C2 for potentially dangerous conditions; either makes the report unsatisfactory. C3 indicates an improvement recommendation and does not, by itself, make the report unsatisfactory. FI means further investigation: on the BS 7671:2018+A4:2026 model form it is advised rather than required and, like C3, does not on its own make the report unsatisfactory, although current GOV.UK guidance for rented homes in England still expects landlords to have FI findings investigated. For landlords, EICR C1 C2 C3 and FI Codes Explained is not simply a list of labels: the distinctions determine which findings require safety work, further investigation or only a recommended improvement. The Electrical Safety First Best Practice Guide 10, listed in the official guidance below, provides the technical context for periodic inspection in rented accommodation.

If there is immediate danger, do not wait for administration or an email trail to be completed before arranging appropriate protective action. For other required findings, the report should state what needs investigating or correcting, and the landlord should obtain professional advice if any observation or limitation is unclear. Do not pressure an inspector to change a classification simply to achieve a satisfactory label.

Deadlines after an unsatisfactory EICR

Required remedial work or further investigation must be carried out within 28 days of the inspection and testing, or within the shorter period the report specifies; the clock does not start when the report is opened. A C1 danger needs immediate protective action rather than waiting for day 28. The duties are set out in the Electrical Safety Standards Regulations 2020 and the current government guidance, both listed below.

Our guide What Happens After an Unsatisfactory EICR takes each step in order: prioritising C1, C2 and FI findings, arranging the repairs, handling delays or disputed codes, and the records that close the report.

Once the work is complete, obtain written confirmation from a qualified person and give it, with the report, to the tenant and the local council within 28 days. Keep the original EICR with the work records rather than replacing it with a note saying only “passed”.

What electrical safety documents tenants should receive

For covered rental properties in England, an existing tenant must receive a copy of the electrical safety report within 28 days of inspection, and a new tenant must receive it before occupying the home. A prospective tenant who requests the report must receive a copy within 28 days of the request. The landlord must also provide the report to the local authority within seven days of a request and retain it for the required period. These are separate document duties, not alternative ways to satisfy a single deadline.

Where remedial work or further investigation was required, the landlord also needs the qualified person’s written confirmation and must supply it alongside the relevant report as required. The precise documentation may include an installation certificate, a minor-works certificate, a satisfactory follow-up EICR or another suitable written record, depending on the work. Keep the factual description of work and test results intact; do not treat an invoice or a verbal assurance as an equivalent electrical certificate.

A properly managed property file contains the inspection date, the full report and its limitations, the next inspection date, the evidence of any required work, and records of when documents were shared. It should be easy for a replacement managing agent or inspector to understand which recommendations are complete and which remain open. This also provides clarity for tenants who need to know whether a restriction or isolated circuit is still in place.

Electrical safety for HMOs and shared accommodation

Properties occupied by unrelated residents sharing facilities may fall within the electrical safety rules even when accommodation is arranged room by room. Additional HMO licensing and management duties can apply, depending on the property, number of occupiers and local licensing scheme. The scope of an EICR for the rented dwelling and the obligations relating to communal areas or additional equipment should not be assumed to be identical.

For shared properties, HMO Electrical Safety and EICR Requirements extend beyond the date on the most recent electrical inspection report. A managing landlord needs to consider access to individual rooms, changing occupancy, common electrical supplies, fire-safety interfaces and whether an additional licensing condition imposes relevant requirements. The statutory rented-sector electrical inspection rules do not, by themselves, cover every communal area in a block, but those areas may still be subject to duties under other housing and safety legislation. The GOV.UK guidance for private and social rented homes distinguishes these responsibilities.

Where a property has several occupiers or separate access permissions, agree the inspection scope and attendance logistics before the visit. If some locations cannot be inspected, the contractor should record the limitation and advise what further work is needed rather than implying that every circuit has been tested.

Managing multiple rental properties and letting agents

The simplest way to prevent missed EICR dates is to record the next inspection date and assign responsibility for arranging the appointment, receiving the report and following through on any findings. Letting agents managing several properties should keep records that link the inspection, remedial work, tenant notifications and completion evidence to the correct address and occupancy. A contractor may visit multiple premises in one day, but each property requires its own clear scope and report.

For a managing agent, EICR Scheduling for Letting Agent Portfolios means coordinating inspection dates, tenant access and contractors, without treating a completed appointment as proof that every compliance duty has been fulfilled. If an inspection is delayed by denied access, retain the reasonable attempts to arrange entry, the alternatives offered and relevant correspondence. Official guidance recognises reasonable-steps provisions in certain circumstances, but poor administration alone is not a substitute for compliance.

TRACEFORM also has a dedicated page for electrical support for landlords and managing agents, covering fault reports, access arrangements and electrical work across managed properties. For portfolio enquiries, share the property locations and the records already held so that inspection and repair requirements can be discussed separately.

Responding to faults between scheduled inspections

A current EICR is a snapshot, not a reason to dismiss an electrical problem reported later. Heat at a socket, crackling, repeated tripping, damaged wiring or electrical equipment affected by water all warrant a response proportionate to the risk. Ask the tenant for safe observations, tell them to keep clear of dangerous equipment, and arrange competent attention. Do not ask an occupier to remove covers, touch conductors or repeatedly reset a protective device to recreate a fault.

If the property has fire, smoke, exposed live parts, an electric-shock injury or another immediate danger, occupants should get to safety and call 999 where appropriate. For a problem that requires professional diagnosis without an active fire, TRACEFORM offers electrical fault finding as a separate service. A focused fault visit may produce a repair record, but it should not be described as a full periodic EICR unless that inspection and testing was actually carried out.

Once the electrician has assessed the problem, the landlord should know whether the area can be used, whether a circuit remains isolated and whether further remedial work or inspection is required. That decision should be communicated to the tenant and documented in the property record; it should not be inferred from the mere fact that power was restored.

How EICR costs and remedial work are assessed

An EICR quotation should reflect the type and size of property, the number and accessibility of circuits, the available records and any known complications. Inspection and testing is a defined task; the cost of repairing an identified defect is a separate question. A price that appears to include unlimited repairs, certification and access work should be checked carefully to understand what has actually been agreed.

A sound quotation distinguishes the inspection fee, access arrangements and any work that may only be known after testing. Sometimes a satisfactory inspection needs no remedial work. In other cases, a limited repair, further diagnosis or a larger upgrade may be justified by the actual observations. A report should not automatically become a sales case for replacing a consumer unit or rewiring the entire property.

Ask for the scope and output of the inspection in writing, including the form of report and how limitations are explained. If remedial work is proposed, obtain a written description of the defects, what will be repaired or isolated, what testing follows and which documents you will receive. This provides a fair comparison between contractors and gives the tenant a clearer account of the work planned.

BS 7671 and updates to electrical safety standards

The technical benchmark for electrical installations is BS 7671, the IET Wiring Regulations. The current edition incorporates Amendment 4:2026; its six-month transition period ended on 15 October 2026. The IET’s BS 7671 update guidance, listed below, explains the publication and transition. This does not make every installation built under earlier requirements automatically unsafe, and it does not remove the need for a competent, evidence-led assessment of any existing installation.

The legal responsibilities and technical standards can also change over time. Landlords should use the most recent official government guidance when arranging an inspection, particularly where social housing transitional arrangements or new duties are involved. For readers in Scotland, Wales or Northern Ireland, different legal frameworks may apply, so England’s inspection and document deadlines should not be presented as universal UK law. Letting a home in M32? See our page for an electrician in Stretford.

Talk to a qualified electricianCall 07777 301818
  • 24/7 emergency response
  • NICEIC registered
  • Trusted by locals

The duties at a glance

What landlord electrical compliance involves

The inspection cycle, the classification codes, the remedial window, the document duties, shared housing and faults between inspections.

  • Hand marking a date in a planner beside a property file on a bright deskFive-year inspection cycleFixed electrics must be inspected and tested at least every five years, or sooner when the report sets a shorter interval.
  • Electrician pointing to an observation in an inspection report on a clipboardC1, C2, C3 and FI codesC1 and C2 need safety work and make the report unsatisfactory; on the 2026 form FI asks for investigation and, like C3, does not fail the report alone.
  • Electrician replacing a socket in a rental kitchen with a lock-off on the consumer unitThe 28-day remedial windowRequired work runs from the inspection date, not from when the report is opened, and immediate danger cannot wait for day 28.
  • Electrician placing an inspection report into an envelope at a dining table with a laptop openTenant and council documentsExisting tenants within 28 days, new tenants before occupation and the council within seven days of a request.
  • Electrician checking circuit labels at a consumer unit in a shared house corridorHMOs and shared housesRoom-by-room lets, communal supplies and licensing conditions can widen what needs inspecting and recording.
  • Electrician testing a heat-marked double socket in a rental bedroom while the tenant watchesFaults between inspectionsHeat, crackling, repeated tripping or water at a fitting needs its own assessment, whatever the date on the last EICR.

Signs a rental property needs action now

Passed deadlines, open C1, C2 or FI codes, missing paperwork and new fault reports all need following up.

  • The next inspection date on the EICR has passed or is close
  • A report marked unsatisfactory with C1, C2 or FI observations
  • No written confirmation that required remedial work was completed
  • A tenant reports heat, scorching, crackling or repeated tripping
  • Water affecting sockets, lights or fixed wiring
  • No record that tenants received the current report

Landlord checklist

Four steps from inspection to closed file

Check the dates, prepare access, act on the findings in time and keep the records together.

  1. 1Check the dates and the fileFind the current EICR, its recommended next inspection date, any open C1, C2 or FI observations and proof that tenants received the report.
  2. 2Prepare access and informationGive the electrician the address, access contact, previous report and certificates, and agree short circuit isolations with the tenant in advance.
  3. 3Act on the findings in timeArrange required remedial work or further investigation within 28 days of the inspection, or sooner if the report says, and act at once on immediate danger.
  4. 4Share and keep the recordsSend the report and written confirmation of completed work to tenants and, on request, the council, then file everything together by property.
Letting agent with a property file reviewing an inspection report with an electrician holding a tablet An appointment is not a completed duty

Call 999 for fire or immediate danger

  • Do not ask a tenant to remove covers or touch conductors
  • Do not let a quotation stand in for confirmation of completed work
  • Do not pressure an inspector to change a classification
  • Do not treat a current EICR as proof a new fault is safe

Occupants should leave the property if there are flames, smoke or a developing electrical fire.

Send the current report

A copy of the EICR and any open observations helps us advise on the next step before we attend.

  • The full EICR with its limitations and next inspection date
  • Written confirmation of any remedial work or investigation
  • Dates the report was sent to tenants and the council
  • Access attempts and correspondence if entry was refused
  • Installation or minor-works certificates for later work
Safe observations onlyTenants should not touch hot, wet or damaged equipment, exposed conductors or burnt accessories.Request a callback

When a tenant reports dangerFor fire, smoke, exposed live parts or an electric-shock injury, occupants should get to safety and call 999. Never ask a tenant to remove covers, touch conductors or repeatedly reset a protective device.

Do not wait for the next EICR if you see these

For smoke, flames or fire, leave and call 999.

  • Fire, smoke, arcing or exposed live parts
  • A person has received an electric shock
  • Heat, scorching or crackling at a socket or the consumer unit
  • Water affecting sockets, lights or fixed wiring
  • A C1 observation recorded as danger present

Trust & expertise

Why landlords and agents trust TRACEFORM

Local, qualified and evidence-led.

This guide is written by our founder, checked by our electricians and draws on current GOV.UK guidance and legislation.

  • NICEIC registeredCertificated and audited
  • Qualified & insuredFully qualified electricians
  • Planned and emergency workEICRs, fault finding and remedial repairs
  • Evidence-led guidanceBased on GOV.UK, legislation and IET guidance

Written by

Ali Vahidi

Founder & Managing Director

  • Founder of TRACEFORMStarted the company in Manchester and runs it day to day.
  • Accountable for this guidePublishes it, keeps it current and answers questions about it directly.
  • Checked by our electriciansTechnical content is checked by TRACEFORM’s NICEIC-registered electricians.
Ali Vahidi, Founder & Managing Director

“Landlords often treat the EICR as the whole job. It is the start of one: the codes decide what must be done, the dates decide when, and the paperwork proves it happened. This guide sets out each of those duties in the order you will meet them.”

Last updated

25 Oct 2026

Checked by our NICEIC-registered electricians against current GOV.UK rented-sector guidance and the Electrical Safety Standards Regulations 2020.

Covering five regions with local engineers

BoltonManchesterBuryRochdaleOldhamWiganSalfordTraffordTamesideStockport

Planned inspections and emergency help

We provide planned EICRs and 24/7 emergency electrical support across Greater Manchester, Liverpool, London, Cambridge and Peterborough. Availability and any visit estimate are confirmed for your postcode.

Find electrical help across our five regions
  • Trusted locallyTrusted by local customers and highly rated on Google.
  • Five regionsGreater Manchester, Liverpool, London, Cambridge and Peterborough.
  • Clear recordsReports and remedial confirmation you can pass to tenants and councils.
  • Clear communicationInspection, repairs and costs are explained separately with no hidden costs.

FAQ

Landlord EICR questions

Answers on legal requirements, validity, unsatisfactory reports, deadlines, tenant copies, appliances and letting agents.

Is an EICR legally required for a rented property in England?

For most covered private and social rented homes, the applicable regulations require qualified inspection and testing of the fixed electrical installation at intervals of no more than five years, or sooner if the report specifies. The precise position depends on the tenancy and any relevant exemptions or transitional arrangements.

Does a landlord need a new EICR every time a tenant moves in?

Not automatically. A suitable current inspection report may already be available, but the landlord must check its date, recommendations and whether necessary work has been completed. The new tenant must receive the required report before occupying the home.

How long is an EICR valid for a rental property?

The ordinary maximum inspection interval is five years, but the report can specify a shorter period. Significant faults or changes to the installation may require attention before that next periodic date. The relevant deadline is the one applicable to the property and the inspector’s findings.

What makes an EICR unsatisfactory?

A C1 or C2 observation makes the report unsatisfactory because remedial work is needed. On the 2026 model form an FI is advisory and does not on its own, although GOV.UK guidance for rented homes in England still expects the investigation to be carried out; older forms treated FI as unsatisfactory. A C3 recommendation alone does not make a report unsatisfactory. A qualified person must interpret the report and establish the corrective action required.

How quickly must a landlord put electrical problems right after an EICR?

Required remedial work or further investigation normally has to be completed within 28 days of the inspection and testing, or sooner if the report specifies a shorter period. Serious danger calls for immediate protective action. Once the work is completed, the landlord must obtain and share the appropriate written confirmation.

Do landlords have to give tenants the EICR?

Yes, within the applicable rules: existing tenants must receive it within 28 days of the inspection and new tenants before occupation. Prospective tenants who request it and local authorities also have prescribed access to the report. Keep evidence that the required copies were supplied.

Does an EICR cover a landlord’s appliances?

An EICR primarily concerns the fixed electrical installation. Social landlords have additional statutory requirements for checking electrical equipment supplied under the tenancy. The position for portable appliances in private rentals is not identical to those social-housing rules, although provided equipment must still be safe.

Can a letting agent arrange inspections and repairs on behalf of the landlord?

Yes, subject to the management agreement and access arrangements. The landlord should still ensure the statutory duties are met and that reports, records of completed work and tenant notifications are retained. Clear delegation of tasks is useful; it does not remove the responsibility to follow up unresolved findings.

Is a new consumer unit always necessary after an unsatisfactory report?

No. The appropriate remedy depends on the actual observation. Some problems can be repaired locally, while others require further testing or a more extensive change. The electrician should explain the evidence before recommending replacement.

  • NICEIC registered
  • Arrival estimate confirmed
  • Written findings

Request a secure callback

Tell us about the property, the current report and any deadline and we’ll call you back. No obligation, just helpful advice.

What do you need help with?
How urgent is it? optional
  • NICEIC
  • 24/7
  • Clear prices

Your details are only used to respond to your enquiry

  • Your details are secure and never shared
  • We’ll typically call you with an estimate confirmed when you call
  • No obligation just helpful advice

Get it inspected

Need a landlord EICR or an electrical assessment?

Share the postcode, whether the property is tenanted, the current EICR and any deadline. Our qualified electricians provide planned inspection and testing and 24/7 emergency fault help across our five regions.

  • 24/7Emergency help, day or night
  • Qualified & insuredNICEIC Registered Electricians
  • Five regionsPlanned inspections and emergency fault help
Electrician handing a report folder to a landlord at the front door of a brick house
Landlord EICRs and electrical assessments across our five regions

Information to have ready when you call

A few property details and the current report help us confirm the right service and the timescale.

  • Your full postcodeSo we can confirm coverage and availability
  • Tenancy and accessWhether it is tenanted and who can give access
  • Current EICRThe full report, including any open observations
  • Inspection deadlineThe next inspection date or remedial deadline
  • Reported concernsHeat, scorching, tripping, water or damage
  • Property typeFlat, house, HMO or a portfolio of addresses

What happens when you contact us

Clear advice, the right type of visit and written results you can share.

  1. 1Get in touchCall or WhatsApp with the address, the current report and any deadline.
  2. 2We confirm what is neededA planned EICR, targeted fault finding or a separately agreed repair.
  3. 3Written resultsA clear report or confirmation of completed work for tenants and your file.
  • Trusted by local customers5.0 rated
  • Proudly coveringGreater Manchester, Liverpool, London, Cambridge and Peterborough

Need help now?

Inspection due, report failed or a tenant reporting a fault? Get qualified help today.

Our qualified and insured electricians provide planned EICRs and 24/7 emergency response across Greater Manchester, Liverpool, London, Cambridge and Peterborough. For emergency callouts, the callout cost is agreed before travel.

  • 24/7emergency response
  • Qualified & insuredelectricians
  • Local engineersacross Greater Manchester, Liverpool, London, Cambridge and Peterborough
  • Locally trustedlocal customers
Electrician handing a report folder to a landlord at the front door of a brick house