Storage heater not charging overnight: the usual causes
A storage heater only charges while its off-peak circuit is on overnight. If every heater is cold at breakfast, suspect the supply: a timeswitch that lost its settings in a power cut, a failed meter switching contact, or an off-peak circuit not reconnected after a meter exchange. Older radio-controlled meters are being phased out, and heaters on them can stop charging until your supplier replaces the meter.
If one heater is cold and the rest are warm, the fault is usually inside it: a failed element, a tripped thermal cut-out, a faulty input thermostat or a burnt terminal. We confirm which with a clamp meter during the charging period.
Hot all night but cold by the evening
Heat is escaping too early. An output dial left high, a damper that no longer closes or a fan running at night will empty the core. Turn the output to minimum before bed; if it still runs out, we check the damper and fan.
Electric radiator not working
A blank display usually means no supply, so we check the fused spur, wiring and the radiator's own fuse. A working display with a cold panel points to the element, thermostat, controller or an internal cut-out.
Electric boiler tripping RCD or not firing
An electric flow boiler heats water with elements switched by contactors. If the RCD trips as it fires, an element's insulation is usually breaking down, or moisture has got inside, so we test each element's insulation resistance. A boiler that never heats may have a failed contactor, a tripped overheat thermostat or a dead element. Leaks, low pressure or pump faults are for a heating engineer or plumber.
Electric underfloor heating not working
A cold floor is most often the thermostat or floor probe, and both can usually be replaced from the wall. If the heating trips the RCD, the cable may be damaged by a fixing, drill or tiling work. We measure element and insulation resistance against the manufacturer's figures and explain the options before anything is lifted.
Storage heater repair or replacement?
Elements, thermostats, cut-outs, dampers and fans can be replaced on most heaters, so repair is often sensible. Replacement makes sense when parts are no longer made or the casing is damaged. Heaters installed before 1974 may contain asbestos; we will not dismantle those, and a specialist must remove them.