Most bathroom fans come on with the light. A fan with an overrun timer needs a permanent live to stay powered and a switched live from the light switch to tell it when to start. Both usually pass through a three-pole fan isolator, often a small switch outside the bathroom that people mistake for a spare light switch and turn off.
So we start there: an isolator off or failed, a blown fuse in a fused spur, a loose connection, or a switched live that never reaches the fan. If the supply is healthy, the timer board or motor has usually failed. A fan that hums without turning normally has seized bearings.
Running on for 15 or 20 minutes is normal, and Approved Document F expects at least 15 minutes in a room without an openable window. A fan that never stops usually has its overrun at maximum, a failed timer board, or its switched live and permanent live crossed. Some modern fans are designed to tick over all day and boost when needed, so check before switching one off.
When the extractor fan humidistat is the cause
An extractor fan humidistat starts the fan above a set humidity and often overrides the timer. Set too sensitive, or coated in dust, it can run for hours in a damp house. We adjust the setting, check the sensor and replace the fan or module if the board has failed.
A noisy extractor fan is usually worn: grinding means tired bearings, a whine means a motor fighting a blocked duct, tapping in wind is often the backdraught shutter. Loft inline fans can drum against joists when mountings loosen.
If it sounds fine but steam hangs about, check the air path. Loft ducting gets crushed or pulled off, outside grilles block, and a door with no gap underneath starves the fan. Approved Document F sets minimum intermittent extract rates of 15 litres per second for a bathroom and 30 or 60 for a kitchen, depending on the cooker hood.
Kitchen fans fail in the same ways, with grease added. For cooker hoods we handle the electrical side: the fused connection unit or switch, the flex and the supply. If the supply is healthy and the hood has failed, we tell you so you can arrange the appliance repair.
A bathroom extractor fan replacement starts with a fan with enough airflow and the right controls: timer, humidistat, pull cord or occupancy sensor. In zones 1 and 2 it needs a suitable IP rating, and some positions call for a SELV fan with its transformer outside the zones. We confirm RCD protection, keep the isolator out of reach of the bath and shower, and check the duct.
A swap on existing cabling is usually straightforward. A new fan on a new cable route may be notifiable under Building Regulations Part P; we tell you before starting and supply the certificates.