Fire, smoke, lightning and surges can damage cables and fittings in ways you cannot see. Before anything is switched back on, the installation needs making safe and testing. We do both, then put the findings in writing for your insurer, landlord or loss adjuster.
What an electrical report for insurance claim purposes covers
Insurers want to know what is damaged, what the repair involves and whether the installation is safe meanwhile. Our report answers that in plain English, backed by readings and photos taken on the day.
- What you told us happened and what we were asked to look at
- How we made it safe and which circuits are isolated
- What we found, fitting by fitting, with photos and test results
- What must be replaced and why, and an itemised quote
Electrical fire damage: what we look for
Heat travels. A socket that caught fire may have damaged the cable behind it or the next socket on the ring, and firefighting water reaches places the fire did not. We follow the circuit from the obvious damage, checking accessories, junctions and the board. Where a cable cannot be seen without opening a wall, the report says so.
Electrical damage from lightning strike or a surge
Lightning does not have to hit the house. A strike near overhead lines can send a surge into the wiring, and routers, televisions, boilers and alarm panels may fail at once or weeks later. We test the circuits, check accessories for heat marks and check failed equipment where it is safe to.
Power surge damage from the supply
Power surge damage can also come from the supply, for example a network fault or lost neutral pushing the voltage too high. Lights flaring and several appliances failing together are typical signs. Report suspected network faults on 105; in the North West that reaches Electricity North West. We record the supply voltage we measured.
The tests behind every finding
- Insulation resistance, to show whether heat, water or a surge has weakened the cable insulation
- Continuity of protective conductors, to confirm the earth path is whole
- Polarity, to confirm line and neutral are the right way round
- Earth fault loop impedance and RCD trip times, to confirm the protection still disconnects quickly
Why the insurer decides, and what we will not write
We report facts: what we saw, what we measured and what the repair involves. If testing points to a likely cause, the report says so and why. If it does not, we will not guess, because an unsupported opinion can harm a claim. Cover is the insurer's decision under your policy.