Mains electricity should never reach anything you can touch. A shock or tingle means a conductor is live where it should not be and the protection has not cut the power as designed. We find that path, repair it and prove by testing that it has gone.
Why something safe can give you a shock
Metal parts are connected to the green-and-yellow earth. If a live conductor touches them, fault current flows to earth and the breaker or RCD switches off fast. You get a shock when metal becomes live and that earth path is broken, weak or missing. Common causes are a loose earth at a fitting, a cable pierced by a nail or screw, bonding removed during building work, a faulty appliance or a supply neutral fault.
Electric shock from light switch or socket
An electric shock from light switch plates usually means a metal plate with no earth, a fixing screw through the cable, or damage at the back box. Many older lighting circuits have no earth, which is fine with plastic switches but not metal ones fitted later. An electric shock from plug socket faceplates points to a cracked accessory, a loose terminal or a broken earth on the circuit. One snap after walking on carpet is usually static; a repeatable buzz is mains.
Electric shock from tap, sink or bath
Pipes are not part of the wiring, so an electric shock from tap metalwork means voltage reached the pipes from a live fault, such as a damaged immersion heater cable, while the bonding is missing or broken. Plastic pipe sections can leave copper runs unbonded. Older bathrooms have supplementary bonding clamps on taps and pipes; current rules allow it to be left out only when every circuit is RCD protected and main bonding is correct.
Earth bonding gas meter and water pipe checks
Main bonding links incoming metal gas and water pipes to the main earthing terminal. The gas clamp belongs on the house side of the meter, close to it and before any branch; the water clamp near where the pipe enters. It often goes missing after meter changes, new boilers or kitchen refits. Never refit it yourself.
Tingle from appliance casings
A tingle from appliance casings, such as a washing machine or metal kettle, usually means an internal fault, made dangerous by a poor earth. Switch it off and unplug it only if the plug and socket are dry and undamaged. We test the circuit and the appliance.
Shocks in several places and PME earthing
Many homes have a PME earth supplied through the network's neutral. If that neutral breaks, earthed metalwork can rise in voltage, with tingles in several rooms and lights dimming or brightening. Keep away from metalwork and call straight away; a neighbour having power does not rule out a network fault.
When to get an electrician to check earthing
Get an electrician to check earthing after any shock, and after work that may disturb it: a new kitchen or bathroom, a meter change or new pipework. If nothing tripped, the RCD may be missing or faulty, so we time it with a tester. Landlords in England must have inspections at least every five years and complete required remedial work within 28 days or sooner.